Description It is a long established too fact that is one reader will bee the distracted by the readable content of the pages when this looking at its layout. The point of using Lorem and Ispum is that it is has normal distribution of letters, as there opposed to using contents here. Lorem is an long established to fact that is one reader will be the distracted and products from global and local market.

Add to Wishlist
Add to Wishlist

Description

The Philips Respironics Ventilator Trilogy 100 system provides intermittent or continuous ventilatory support for patient’s care who may require mechanical ventilation. Trilogy 100 is designed for pediatric adult patients weighing at least 11 lbs (5kgs).
Ventilation Trilogy is intended to be used in hospital, institution, home and portable applications like gurneys and wheelchairs, and may be for both non invasive and invasive ventilation. It is not intended to be used as a transport ventilator.
The system is mostly recommended to be used only with different combinations of Philips Respironics-approved patient circuit accessories, like humidifiers, interface devices, circuit tubing and water traps.

• Innovation, versatility, and reliability from a trusted industry leader

• Screen displays are easy to read

• Two circuit options for simple, flexible use

• Easy to set up and easy to use

• Passive circuit option for passive exhalation

• Giving you volume targeting options with AVAPS-AE

• Giving patients freedom its mouthpiece ventilation (MPV)

• Proven technology for non-invasive therapy with Digital Auto-Trak

• Direct View Ventilation Management Reporting Software for prescription management

Specifications of Philips Trilogy :-

Alarms
  • • Apnea rate: Off; 10 to 60 s
  • • Circuit disconnect: Off; 5 to 60 s
  • • High tidal volume: Off; 50 to 2000 ml
  • • Low tidal volume: Off; 40 to 2000 ml
  • • High minute ventilation : Off; 1.0 to 99 l/min
  • • Low minute ventilations: Off; 0.2 to 99 l/min
  • • High respiratory rate: Off; 4 to 80 BPM
Measured patient parameters
  • • Respiratory rate: 0 to 80 BPM
  • • Minute ventilation: 0 to 99 l/min
  • • Vte/Vti: 0 to 2000 ml
  • • Leak rate: 0 to 200 l/min
  • • Peak inspiratory pressure : 0 to 99 cm H₂O
  • • Peak inspiratory flow : 0 to 200 l/min
  • • Mean airway pressure : 0 to 99 cm H₂O
  • • Patient triggered breaths : 0 to 100 %
  • • I:E ratio: 9.9:1 to 1:9.9
Dimensions and weight
  • • Dimensions: 16.68 cm L x 28.45 cm W x 23.52 cm H (6.6″ L x 11.2″ W x 9.3″ H)
  • • Weight: 5 kg (11 lb)
Control accuracy
  • • Tidal volume: 50 to 2000 ml
  • • Circuit types : Active with PAP; Passive
  • • Breath rate: 0 to 60 BPM for AC mode; 1 to 60 BPM for all other modes
  • • Ventilation types : Pressure and Volume
  • • Inspiratory time : 0.3 to 5.0 s
  • • Volume modes : AC; SIMV (w/PS); CV; AC-MPV
  • • Pressure modes : CPAP; S; S/T; T; PC; PC-SIMV (w/PS); PC-MPV; AVAPS-AE
  • • Rise time : 1 to 6
  • • Pressure : 4 to 50 cm H₂O
  • • IPAP : 4 to 50 cm H₂O
  • • Ramp start pressure : 0 to 25 cm H₂O for active circuits; 4 to 25 cm H₂O for passive circuits; 4 to 19 cm H₂O in CPAP
  • • Ramp length : Off; 5 to 45 minute(s)
  • • PEEP/EPAP for active circuits : 0 to 25 cm H₂O
  • • PEEP/EPAP for passive circuits : 4 to 25 cm H₂O
  • • Flex: Off; 1 to 3
  • • CPAP for passive circuits : 4 to 20 cm H₂O
  • • Flow trigger sensitivity : 1 to 9 l/min
  • • Flow cycle : 10 to 90 %
  • • Apnea rate : 4 to 60 BPM
  • • Pressure support differential : 0 to 40 cm H₂O

TERMS AND CONDITIONS FOR RENTING MEDICAL EQUIPMENTS :-

1. Rental Amount: It is shown in the product page.
2. Delivery and Pickup Charge: Extra amount will be charged only once while delivering the equipment. Which will be conveyed to the client prior delivery.
3. Security Deposit: A post dated cheque of ₹150,000/- must be handed to the executives at the time of delivery of equipment as per the rental agreement.
4. Rental Period:- The period must be selected at the initial conversation and no refund will be initiated prior to closure.
5. Rental Amount: The amount must be paid in advance and any renewal and cancellations must be informed in advance of at least 48 hours.
6. If any malfunction must be informed to the company and necessary replacement will be made within 48 hours. Handling the equipment with care because any physical damage caused from the customer will be considered negligence hence the post dated cheque will be claimed and the amount will be used for repair and the remaining amount will be refunded to the customer.
7. No refund will be initiated in any case.
8. The equipment is the sole property of lyf medicare sales and services pvt ltd. The price paid is only to use the product as per the rental agreement for the period. The equipment shall be returned to lyf medicare sales and services pvt ltd after the rental period.
9. Any legal dispute in gurgaon jurisdiction only.
10. Above given information is for educational purposes only. It is important to consult a doctor prior to selecting your device.

NOTE:

The picture shown on the product page is for representation purposes only. The actual product delivered on rent may not look the same but will serve the same purpose as mentioned.
The product delivered on rent is not a new product so it must be used multiple times but in good condition for the usage. Equipment may be replaced by the company with prior intimation if service interval falls between the rental period

Reviews

There are no reviews yet.

Be the first to review “Philips Trilogy”
All fields marked with an asterisk (*) are required

X
Skip to content