CMS8000 patient monitor has abundant functions that can be used for clinical monitoring with adult, pediatrics, neonate or veterinary. This device can monitor parameters such as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc.

Add to Wishlist
Add to Wishlist

Description

Features : 

  • Suitable for adult, pediatric and neonatal patients
  • 12.1” TFT color LCD
  • Parameters: ECG, NIBP, SpO2, Pulse Rate, Respiration, Temperature and IBP (upgradable)
  • Maximum 8-channel waveform synchronous display
  • Graphic and tabular trends for 96 hours for all formats
  • Multi-screen format
  • Powerful data management and storage capacity, 500 NIBP measurement data can be storage and recall
  • AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring
  • Visual and Audio alarms, adjustable.
  • Measurement Mode: Manual/Auto/Stat

Specifications : 

ECG:

  • 5 lead or 12 lead selectable
  • Input: 5 lead; RA, LT, RL, LL, V or R, L, N, F, C
  • Lead selection: I, II, III, aVR, aVL, aVF, Vx, CAL
  • Gain Selection: ×25, ×0.5, ×1, ×2, auto
  • Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
  • Accuracy: ±1bpm or ±1% whichever is grater
  • Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
  • Calibration signal: 1mV±5%
  • Operation modes, Diagnostic, Monitor, Surgery
  • Heart rate range: Adult: 15-3000bpm; Pediatric/Neonatal: 15-350bpm
  • Measurement range: -2.0mV to 2.0mV
  • ST detection: YES,
  • Arrhythmia analysis: YES
  • Alarm: YES, audible and visual alarm, alarm events recallable.

 NIBP:

  • Method: Oscillometry
  • Mode: Manual/Auto/STAT
  • Measurement Range: adult 10-270mmHg
  • Measurement Type: Systolic, Diastolic, Mean
  • Resolution: 1mmHg
  • NIBP Accuracy: Mean ±5mmHg, SD ±8mmHg
  • Alarm: SYS/DIA/MEAN

Respiration:

  • Method: RA-LL impedance
  • Measurement range: Adult: 0-120rpm, Paediatric/Neonatal: 0-150rpm
  • Apnea Alarm: YES

SpO2:

  • Measurement range: 0%-100%
  • Accuracy: ±2% (70%-100%); 0%-69% unspecified.
  • Alarm range: 0-100%

Pulse Rate:

  • Measurement range: 10 – 270
  • Resolution: 1bpm
  • Accuracy: ±2pm or ±2%

Temperature:

  • Resolution: 0.2 0C
  • Channel: Dual-channel
  • Measurement range: 0-50 0C

IBP (Upgradable):

  • Channel: 2
  • Pressure transducer: Sensitivity: 5(mV/V/mmHg)
  • Transducer sites: ART, PA, CVP, RAP, LAP, ICP
  • Alarm range: -10 to 300 mmHg